Acrel Data Center Multi-channel Energy Meter Application in Netherlands
Project Overview
As the global fossil energy (oil and coal) is approaching exhaustion, pollution is becoming more and more serious, and the climate is warming, etc., many countries and regions around the world have successively issued regulations and policies, which have promoted the development of the PV industry.
However, due to the large number and concentration of the PV monitoring circuits, a large number of power distribution room space is occupied.
Acrel multi-channel energy meter has a high level of integration. A single module can monitor 48 circuits, and at the same time, it can also be matched with switch acquisition module to realize the circuit monitoring of PV system.
One PV system company in the Netherlands that provides PV systems for a wide variety of buildings.
In the PV monitoring system of the customer, the current situation of more than 300 loops need to be monitored at the same time. These loops are centrally in the distribution room. In order to collect information more effectively, the customer chooses the product of AMC16Z-FAK48, so as to complete the monitoring of the circuit without adding cabinets.
Related Products
AC networking
AMC16Z-ZA data center AC incoming line monitoring device
● Designed specifically for the power supply management of server in the data center
● Measure A+B independent 2 channels three-phase inlet
● U, I, P, Q, S, PF, kWh, kvarh
● 2-63rd harmonic
● RS485, Modbus-RTU communication
● CE certification
● Din rail 35mm installation

AMC16Z-FAK24 data center AC outgoing line monitoring device
● Designed specifically for the power supply management of server in the data center
● Power supply by AMC16Z-ZA
● Measure A+B independent 24 circuits
● U, I, P, Q, S, PF, kWh, kvarh
● 2-31st Harmonic
● RS485, Modbus-RTU communication
● Din rail 35mm installation

AMC16Z-FAK48 data center AC outgoing line monitoring device
● Designed specifically for the power supply management of server in the data center
● Measure A+B independent 48 circuits
● Power supply by AMC16Z-ZA
● U, I, P, Q, S, PF, kWh, kvarh
● 2-31st Harmonic
● RS485, Modbus-RTU communication
● Din rail 35mm installation

DC networking
AMC16Z-ZD data center DC incoming line monitoring device
● Designed specifically for the power supply management of server in the data center
● Measure A+B independent inlet circuit
● U, I, P, Q, S, PF, kWh, kvarh
● RS485, Modbus-RTU communication
● CE certification
● Din rail 35mm installation

AMC16Z-FDK24 data center DC outgoing line monitoring device
● Designed specifically for the power supply management of server in the data center
● Power supply by AMC16Z-ZD
● Measure A+B independent 24 circuits
● RS485, Modbus-RTU communication
● Din rail 35mm installation
● CE certification

AMC16Z-FDK48 data center DC outgoing line monitoring device
● Designed specifically for the power supply management of server in the data center
● Power supply by AMC16Z-ZD
● Measure A+B independent 48 circuits
● RS485, Modbus-RTU communication
● Din rail 35mm installation
● CE certification

On Site Installation Diagram
Structure